IDT82V3202
EBU WAN PLL
Functional Description
32
September 11, 2009
phase locked to any input clock. The frequency offset acquiring method
is selected by the MAN_HOLDOVER bit, the AUTO_AVG bit and the
3.10.1.5.1 Automatic Instantaneous
By this method, the T0 DPLL freezes at the operating frequency
when it enters Holdover mode. The accuracy is 4.4X10-8 ppm.
3.10.1.5.2 Automatic Slow Averaged
By this method, an internal IIR (Infinite Impulse Response) filter is
employed to get the frequency offset. The IIR filter gives a 3 dB attenua-
tion point corresponding to a period of 110 minutes. The accuracy is
1.1X10-5 ppm.
3.10.1.5.3 Automatic Fast Averaged
By this method, an internal IIR (Infinite Impulse Response) filter is
employed to get the frequency offset. The IIR filter gives a 3 dB attenua-
tion point corresponding to a period of 8 minutes. The accuracy is
1.1X10-5 ppm.
3.10.1.5.4 Manual
By this method, the frequency offset is set by the
T0_HOLDOVER_FREQ[23:0] bits. The accuracy is 1.1X10-5 ppm.
The frequency offset of the T0 DPLL output is indicated by the
CURRENT_DPLL_FREQ[23:0] bits.
The device provides a reference for the value to be written to the
T0_HOLDOVER_FREQ[23:0] bits. The value to be written can refer to
the value read from the CURRENT_DPLL_FREQ[23:0] bits or the
tering.
3.10.1.5.5 Holdover Frequency Offset Read
The offset value, which is acquired by Automatic Slow Averaged,
Automatic Fast Averaged and is set by related register bits, can be read
from the T0_HOLDOVER_FREQ[23:0] bits by setting the READ_AVG
bit and the FAST_AVG bit, as shown in
Table 18.
The frequency offset in ppm is calculated as follows:
Holdover Frequency Offset (ppm) = T0_HOLDOVER_FREQ[23:0] X
0.000011
3.10.1.6
Pre-Locked2 Mode
In Pre-Locked2 mode, the T0 DPLL output attempts to track the
selected input clock.
The Pre-Locked2 mode is a secondary, temporary mode.
Table 17: Frequency Offset Control in Holdover Mode
MAN_HOLDOVER
AUTO_AVG
FAST_AVG
Frequency Offset Acquiring Method
0
don’t-care
Automatic Instantaneous
1
0
Automatic Slow Averaged
1
Automatic Fast Averaged
1
don’t-care
Manual
Table 18: Holdover Frequency Offset Read
READ_AVG FAST_AVG
Offset Value Read from
T0_HOLDOVER_FREQ[23:0]
0
don’t-care The value is equal to the one written to.
1
0
The value is acquired by Automatic Slow Averaged
method, not equal to the one written to.
1
The value is acquired by Automatic Fast Averaged
method, not equal to the one written to.